BRAND | BFI AUTOMATION |
Product | 6010-2013-00 |
Internal code | IMP5028740 |
Weight | 1.5 |
Custom code | 84169000 |
Technical specification | <p>OE-Converter 2.0LA GT-ABB<br>for connecting BFI-FOCs</p><p>The flame scanner 2.0LA is designed detect flames on ABB<br>gas turbines and provides flame information to a BFI flame<br>amplifier. This flame scanner is equipped with a multiple-<br>semiconductor sensor and covers the spectral range from<br>UV to IR. The sensitivity can be adjusted separatly for UV<br>and IR range. The flame scanner 2.0LA is housed in an<br>OE-Converter housing for the connection of a BFI fibre<br>optic cable (FOC) or lance (FOL).</p><p>Technical details:<br>- Spectral Range: 300 - 2700nm<br>- Operating mode: continuous operation<br>- Viewing Angle: 2,7° with lens probe SKL<br>and FOC/FOL<br>- Self Checking: once per second<br>- Power Supply: 24V DC<br>- Current consumption: approx. 200mA<br>- Ambient Temperature: -20°C to +70°C<br>- Cable Connection: Harting Plug<br>- Dimensions [mm]: L 122 x W 120 x H 90<br>- Housing: aluminum, RAL5010, IP 65<br>- ATEX Zone 2: II 3 G ec IIC T4 Gc X<br>- Gain control: automatic (AGC)<br>- Frequency control: automatic (AFC)<br>- SIL certification: SIL3 in combination with flame<br>amplifier 3001, 3001D or 3001S<br></p> |