A. Kirchner & Tochter GmbH.png |
(As previous serial number 76256-01-03, GRA87000348, insert member PE-butt welding sleeve DN40, size 36)
ROTEX GS 65 ST-H clamping hub 2.6 Ø50H7 Nut - KTR
Measurement range 0.2 - 1.2 m³ / h H2O Scale range: 0.00 to 1.2 m³ / h H2O Tube inside diameter: 21.6 mm Flow direction: bottom to top Overall length: 80 mm Differential pressure: 250 mbar Lens: Brass Accuracy: 5% FS Tariff-No .: 90261081 as previous serial number 12131-001-12
(DDM-DS11-MS1 PN 16 G 3/4-i Measurement range 0.2 - 1.2 m³ / h H2O Scale range: 0.00 to 1.2 m³ / h H2O Tube inside diameter: 21.6 mm Flow direction: bottom to top Overall length: 80 mm Differential pressure: 250 mbar Lens: Brass Accuracy: 5% FS Tariff-No .: 90261081 as previous serial number 12131-001-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Range: 2,5 - 15 m³ / h H2O Scale range: 0.00 to 15 m³ / h H2O Tube inside diameter: 53.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-007-12
(DDM-DS11-MS1 PN 16 DN 50 Range: 2,5 - 15 m³ / h H2O Scale range: 0.00 to 15 m³ / h H2O Tube inside diameter: 53.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-007-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Measurement range: 8-48 m³ / h H2O Scale range: 0.00 to 48 m³ / h H2O Tube inside diameter: 82.5 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-010-12
(DDM-DS11-MS1 PN 16 DN 80 Measurement range: 8-48 m³ / h H2O Scale range: 0.00 to 48 m³ / h H2O Tube inside diameter: 82.5 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-010-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate Seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Measuring range: 15 - 90 m³ / h H2O Scale range: 0.00 to 90 m³ / h H2O Inside pipe diameter: 107.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-012-12
(DDM-DS11-MS1 PN 16 DN 100 Measuring range: 15 - 90 m³ / h H2O Scale range: 0.00 to 90 m³ / h H2O Inside pipe diameter: 107.1 mm Flow direction: bottom to top Overall length: 50 mm Differential pressure: 250 mbar Ring S355, aperture 1.4571 Corrosion protection: epoxy esters - paint color oven drying, (RAL 5017) traffic blue satin gloss Corrosion category: C2 Accuracy: 5% FS The device is according to PED for use in designed Category 2 and can also Category 1 and Art. 3.3 are used. Tariff-No .: 90261081 as previous serial number 12131-012-12; Differential DS11 Seat of the indicator: right Display in flow units incl. adapter plate seals NBR Protection: IP54 Compressive strength: max. 16 bar incl. an adjustable external microswitch, changeover contact Load data: U max. 250 VAC; I max. 5 A; P max. 250 VA U max. 30 VDC; I max. 0.4 A; P max. 10 W; Cable connector, 6-pole with screw)
Flowswitches (Kirchner & Tochter) Monitored range : 6 - 20 l/min H2O Inner diameter : 16,1 mm Installation length : 80 mm Y/ref : 1001302
Flowswitches (Kirchner & Tochter) Monitored range : 2 - 6 l/min H2O Inner diameter : 9,2 mm Installation length : 80 mm Y/ref : 1001301
(RA 87-MSK12 PN 10 G 2 1/4-a 250 - 2500 l/h NaOH 30% 30 °C Größe: 36 Baulänge: 366 mm pmax: 8 bar bei 20° C Plexiglasschutz Hulsenmaterial: 1.4301 Koepfe: 1.4571 Fuhrung: 1.4571 Messglas: Borosilicatglas Standardschwebekörper: PTFE mit Magnetkern Standarddichtungen: FPM The DGRL for the Einsatz in Category 2 ausgelegt and kann auch Category 1 and Art. 3.3 eingesetzt werden. The DGRL for the Einsatz in Category 2 ausgelegt and kann auch Category 1 and Art. 3.3 eingesetzt werden. Zoll-Tarif-No.: 90261081)
Differential Flowmeter
Diferential flow meter
Durchflusswächter
FLOW METER
Anschlussverschraubung
Flowmeter with switch
Flowmeter
Flowmeter